Saturday, 7 December 2013

54.Explain the balance drum of a BFP?

Normally the differential pressure between discharge and suction sides of Boiler Feed Pumps are quite high. Due to this, the rotor section experiences very high trust in one direction. The movement of rotor (Axial shift), if it exceeds manufacturer's tolerances, will result in rubbing of mechanical seals and damage the same. A Balance Drum is created by interconnecting suction and discharge sides suitably and the wear out of seals can be inferred by measuring Balance drum pressure.


53.What are the trip commands for a pump?

Typical Trip interlocks for Pumps are: Bearing Temp OR Vibration High,Lube oil press Low, Suction valve Closed , Electrical switch gear faults.

52. What are the trip commands for a Fan?

Typical Trip interlocks for fans are: Bearing Temp OR Vibration High,Lube oil press Low,  Electrical switchgear  faults.

51.What is partial loss of flame?


In a wall fired boiler when a flame scanner sense no flame, the respective burner shut-off valves are demanded to close. If they are failed to close after 10 sec. it is announced as Partial Flame loss.
If the number burners are less than a number which can cause unsafe condition, MFT will be initiated. Sometimes a load factor less then 75% is also ANDed for MFT.
Conservatively some plants are initiating MFT for Partial Flame loss irrespective of any condition of the boiler.